41
Fault
Tolerant
(Raid5)
A minimum of 3 hard disk drives are required to create RAID5. The
data are striped in all hard drives in a RAID5 array and the parity
information is stored in each drive. If a hard disk drive fails, the
array enters degraded mode. The data can be rebuilt from other
member drives after installing a new drive to replace the failed
one.
Fault
Tolerant
(Raid10)
Data are written in stripes across primary disks that have been
mirrored to the secondary disks. A typical RAID 10 configuration
consists of four drives, two for striping and two for mirroring
RAID 10 is supported in DS-8200-RM Pro and DS-4200 Pro Series only.
Select a type of disk configuration, and please click “Apply to execute building new
RAID disk.
Note: Don’t turn off the server or unplug any hard drives when RAID Disk is in
building process.
Please wait. The disk configuration is in a process.
Vista de pagina 45